Public COA audit
BPC-157
Audited September 5, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 92
- Confidence
- 93%
- Panels
- 5/7
- Purity (printed)
- 99.746%
Scored high because the document is mostly consistent but carries soft concerns, broad panel coverage (5/7), and 1 soft concern.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- BC202607
- Identity method
- LC-MS
- Issue date
- 2026-06-10
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
5 of 7 present · 5 passed · 0 failed · 0 reported · 2 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
BPC-157
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.746%
Heavy metals
Tested · passed
Lead, arsenic, cadmium, mercury, or similar limits.
As, Cd, Pb, Hg all Negative
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Tested · passed · core
LAL or chromogenic endotoxin assay.
PASS (≤0.5 EU/mL)
Sterility
Tested · passed
Sterility testing where applicable.
No Growth
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High purity achieved
Batch average purity of 99.746% with consistent results across 5 vials (range 99.576-99.884%), meeting >98% specification
Identity confirmed
LC-MS confirmation of BPC-157 identity with matching molecular formula C62H98N16O22
Batch conformity documented
Individual vial testing results provided for 5 vials with purity and net content measurements
Issue date valid
Certificate issued 2026-06-10, which is before current date 2026-09-05
Lab identification present
Kovera Labs identified with verification URL koveralabs.com/verify, report number KVR-2026-479A0C, and access code GD93E9F
Comprehensive testing suite
Includes purity (HPLC), identity (LC-MS), endotoxin, sterility, heavy metals, and fentanyl screening
Missing microbial and residual solvent panels
No microbial contamination testing (beyond sterility) or residual solvent/water content analysis documented
Professional presentation
Well-formatted report with chromatogram, vial photograph, QR code, and signature from Lab Director
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.