Public COA audit

Klow · GHK-Cu

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
93%
Panels
6/7
Purity (printed)
99.607%

Scored high because the document is mostly consistent but carries soft concerns, broad panel coverage (6/7), and 1 soft concern.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
AMC-KLOW-80-01
Identity method
LC-MS
Issue date
2026-07-16

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

6 of 7 present · 6 passed · 0 failed · 0 reported · 1 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    Klow

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.607%

  • Heavy metals

    Tested · passed

    Lead, arsenic, cadmium, mercury, or similar limits.

    All Negative (As, Cd, Pb, Hg)

  • Microbial

    Tested · passed

    Bioburden / microbial limits testing.

    No Growth

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    Pass (≤0.5 EU/mL)

  • Sterility

    Tested · passed

    Sterility testing where applicable.

    No Growth

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    Blend average purity of 99.607% with consistent vial-to-vial results (99.546% and 99.668%), supported by clean RP-HPLC chromatogram

  • Identity confirmed by LC-MS

    Blend identification performed using LC-MS methodology, confirming product identity as Klow

  • Comprehensive testing panel

    Document includes purity, identity, endotoxin safety, fentanyl screening, microbial sterility, heavy metals, pH, and blend component analysis

  • Batch conformity testing

    Two vials tested from batch AMC-KLOW-80-01 showing consistent purity and net content results

  • Verification system present

    QR code and verification URL (koveralabs.com/verify) provided with access code 1R268SS for independent verification

  • Residual solvent/water content not explicitly tested

    No dedicated residual solvent or water content panel visible, though pH testing (5.2) is present

  • Professional presentation

    Well-structured report with clear sections, reference standards, batch conformity data, blend component analysis, and chromatogram with product photo

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.