Public COA audit
Klow · GHK-Cu
Audited September 5, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 92
- Confidence
- 93%
- Panels
- 6/7
- Purity (printed)
- 99.607%
Scored high because the document is mostly consistent but carries soft concerns, broad panel coverage (6/7), and 1 soft concern.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- AMC-KLOW-80-01
- Identity method
- LC-MS
- Issue date
- 2026-07-16
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
6 of 7 present · 6 passed · 0 failed · 0 reported · 1 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
Klow
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.607%
Heavy metals
Tested · passed
Lead, arsenic, cadmium, mercury, or similar limits.
All Negative (As, Cd, Pb, Hg)
Microbial
Tested · passed
Bioburden / microbial limits testing.
No Growth
Endotoxin
Tested · passed · core
LAL or chromogenic endotoxin assay.
Pass (≤0.5 EU/mL)
Sterility
Tested · passed
Sterility testing where applicable.
No Growth
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High purity confirmed
Blend average purity of 99.607% with consistent vial-to-vial results (99.546% and 99.668%), supported by clean RP-HPLC chromatogram
Identity confirmed by LC-MS
Blend identification performed using LC-MS methodology, confirming product identity as Klow
Comprehensive testing panel
Document includes purity, identity, endotoxin safety, fentanyl screening, microbial sterility, heavy metals, pH, and blend component analysis
Batch conformity testing
Two vials tested from batch AMC-KLOW-80-01 showing consistent purity and net content results
Verification system present
QR code and verification URL (koveralabs.com/verify) provided with access code 1R268SS for independent verification
Residual solvent/water content not explicitly tested
No dedicated residual solvent or water content panel visible, though pH testing (5.2) is present
Professional presentation
Well-structured report with clear sections, reference standards, batch conformity data, blend component analysis, and chromatogram with product photo
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.