Public COA audit

Kisspeptin

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
93%
Panels
3/7
Purity (printed)
99.8%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (3/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
CR-KISS10-2603-1
Identity method
FTIR (USP <197A>)
Sample date
2026-04-02
Issue date
2026-04-05

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    FTIR sample spectrum confirms the presence of Kisspeptin with addition of excipient(s)/fillers

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.8%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    15.6 EU/vial (limit: 40 EU/vial)

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High HPLC purity achieved

    99.8% purity by HPLC (USP <621>) meets specification of ≥98%. This is normal for research-grade peptides.

  • Identity confirmed by FTIR

    FTIR spectrum confirms Kisspeptin with excipients/fillers present, consistent with formulated peptide product.

  • Endotoxin testing performed separately

    Endotoxin testing documented in separate report (IF-824-QSA-TR006-BTL26130-35) dated 4/10/2026, showing 15.6 EU/vial (PASS, limit 40 EU/vial). This is a split-report format common for comprehensive testing.

  • Potency within specification

    HPLC potency assay shows 104.8-108.9% of labeled 10 mg, within 90-110% specification range.

  • Dates are current and consistent

    Issue date 4/5/2026, test date 4/2/2026, endotoxin report dated 4/10/2026. All dates are on or before 2026-09-05 and logically sequenced.

  • Lab information complete

    BTLabs, West Palm Beach FL, with contact info, website, report numbers, QR codes, and dual scientist signatures on both reports.

  • Professional multi-page report with supporting data

    Includes FTIR spectrum, HPLC chromatogram, detailed mass/potency measurements, and separate endotoxin report. Formatting is consistent with professional analytical lab standards.

  • Heavy metals, microbial, sterility, and residual solvent testing not included

    These panels are not present in this report set. The testing purpose statement explicitly notes the scope excludes particulate matter and microbial contamination (page 1), though endotoxin testing was performed separately.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.