Public COA audit

Ipamorelin

Audited July 28, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
85%
Panels
4/7
Purity (printed)
99.77%

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
IPA10-062026-1
Identity method
LC-MS
Sample date
2026-06-03
Issue date
2026-06-05

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

4 of 7 present · 4 passed · 0 failed · 0 reported · 3 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    Ipamorelin

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.77%

  • Heavy metals

    Not on this COA

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Microbial

    Tested · passed

    Bioburden / microbial limits testing.

    No Detectable Microbial DNA

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    Pass (both replicates)

  • Sterility

    Not on this COA

    Sterility testing where applicable.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Residual solvent / water

    Not on this COA

    Residual solvents or water content limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing

Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    HPLC-UV purity of 99.77% (average of two vials: 99.82% and 99.72%) is within normal range for research-grade peptides

  • Identity confirmed by LC-MS

    Mass spectrometry data and chromatogram present showing Ipamorelin identification

  • Batch/lot number present

    Lot IPA10-062026-1 clearly stated with accession number 2606030001

  • Dates within normal range

    Received 2026-06-03, reported 2026-06-05 (2-day turnaround is reasonable)

  • Lab verification unclear

    Freedom Diagnostics Testing website and contact provided, but independent verification of lab accreditation/credentials not possible from document alone

  • Missing heavy metals and residual solvent testing

    No heavy metals panel or residual solvent/water content analysis present. Common for some peptide COAs but represents incomplete safety profile

  • Endotoxin and microbial testing present

    Both endotoxin (LAL assay per USP <85>) and microbial (PCR) testing performed with passing results

  • Professional presentation

    Document includes chromatogram, mass spectrum, QR code, signature, and appropriate disclaimers for research use

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.