Public COA audit

CJC-1295/Ipamorelin

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
95%
Panels
1/7

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (1/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
7-3-45959
Sample date
2025-11-19
Issue date
2025-11-19

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

1 of 7 present · 1 passed · 0 failed · 0 reported · 6 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Not on this certificate file · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Purity

    Not on this certificate file · core

    Reported purity percentage for the analyte.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    < 0.050 EU/mL

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • Endotoxin testing performed

    Chromogenic LAL assay (Endosafe-PTS) performed with result < 0.050 EU/mL, passing specification of < 0.25 EU/mL. Detection range 0.05-5.0 EU/mL, spike recovery 82% (Pass).

  • Endotoxin-only report

    This is a specialized endotoxin testing report from BioRegen. It does not include purity, identity, heavy metals, microbial, sterility, or residual solvent panels. The client (Biolongevity Labs) may have separate reports for those tests.

  • Verification features present

    Report includes Report ID (BL-ENDO-251911-169), Validation Key (BIOLABS2010), QR code for verification, and contact information ([email protected], www.bioregen.com).

  • Test date valid

    Test date 2025-11-19 is within acceptable range (before today 2026-09-05).

  • Sample information complete

    Lot number 7-3-45959, sample concentration 5/5 mg, tested by analyst MARIN using Endosafe nexgen-PTS (SN: 25201216).

  • Professional presentation

    Report follows standard laboratory format with clear tables, analyst signature, and interpretation section explaining the chromogenic LAL assay methodology and acceptance criteria.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.