Public COA audit

Ipamorelin

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
93%
Panels
2/7
Purity (printed)
99.8%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), and 2 soft concerns. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
EB5X5YV
Identity method
FTIR (USP <197A>)
Sample date
2026-03-01
Issue date
2026-03-04

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    FTIR sample spectrum confirms the presence of Ipamorelin with addition of excipient(s)/fillers

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.8%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High HPLC purity

    99.8% purity by HPLC (USP <621>) exceeds ≥98% specification. This is normal for research-grade peptides.

  • FTIR identity confirmed

    FTIR spectrum confirms Ipamorelin presence with excipients/fillers noted.

  • Potency slightly below label claim

    HPLC potency assay shows 9.3 mg (93%) vs. labeled 10 mg. Within 90-110% specification but on lower end.

  • Lot number clearly stated

    Lot EB5X5YV clearly identified on both pages.

  • Dates are valid and consistent

    Sample tested 2026-03-01, report issued 2026-03-04. Both dates are on or before 2026-09-05 (today) and logically sequenced.

  • Testing lab identified

    BTLabs, West Palm Beach, FL with contact information and website provided.

  • Limited scope: purity/identity only

    Testing Purpose explicitly states this COA does NOT provide information on particulate matter, microbial contamination, or endotoxins. This is a purity/identity-scoped report. Missing panels (heavy metals, microbial, endotoxin, sterility, residual solvents) are not tested in this document.

  • Professional formatting with supporting data

    Report includes FTIR spectrum, HPLC chromatogram, retention time data, and dual scientist signatures with digital signature metadata visible.

  • Verification URL provided

    Finnrick verification URL (https://finnrick.com/verify) and test certificate ID (eb5x5yv) provided for independent verification.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.