Public COA audit
Ipamorelin
Audited September 5, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 72
- Confidence
- 88%
- Panels
- 3/7
- Purity (printed)
- 99.8%
Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (3/7), 2 soft concerns, and notable note: "High HPLC purity". To improve: include identity, purity, and endotoxin at minimum.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- CR-IPA10-2603-1
- Identity method
- FTIR (USP <197A>)
- Sample date
- 2026-04-02
- Issue date
- 2026-04-05
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
FTIR confirms Ipamorelin with excipients
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.8%
Heavy metals
Not on this certificate file
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Tested · passed · core
LAL or chromogenic endotoxin assay.
18.7 EU/vial (limit 40 EU/vial)
Sterility
Not on this certificate file
Sterility testing where applicable.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High HPLC purity
99.8% purity is excellent and normal for research-grade peptides
FTIR confirmation
Identity confirmed via FTIR spectroscopy with characteristic peptide bands; excipients noted
Potency below specification
HPLC potency assay shows 59.6%, 90.7%, and 88.5% of labeled 10 mg across three measurements; two of three fall below the 90-110% specification range
Endotoxin testing present
Separate endotoxin report (IF-824-QSA-TR006-BTL26130-24) dated 4/10/2026 shows gel clot test result of 18.7 EU/vial, passing the 40 EU/vial limit
Lot number consistent
Lot CR-IPA10-2603-1 appears on both purity/identity report and endotoxin report
Dates valid
Issue date 4/5/2026 and test date 4/2/2026 are both on or before today (2026-09-05); endotoxin report dated 4/10/2026 is also valid
Lab contact information provided
BTLabs, 5730 Corporate Way Suite 220, West Palm Beach FL 33407; phone (561) 625-0133; website https://btlabtesting.com
Professional presentation
Report includes QR code, signatures, FTIR spectrum, HPLC chromatogram, and detailed test parameters
Missing panels
No heavy metals, microbial contamination, sterility, or residual solvent/water testing reported; testing purpose explicitly states it does not cover microbial or particulate matter
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.