Public COA audit

GHK-Cu

Audited July 29, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
83%
Panels
3/7
Purity (printed)
99.785%

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
0001
Identity method
HPLC with UV Detection Coupled with Mass Spectrometry (LCMS/MS)
Sample date
2025-11-19
Issue date
2025-11-21

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    GHK-Cu confirmed by mass spec [M+2H]2+ 171.05, [M+H]+ 341.10

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.785%

  • Heavy metals

    Not on this COA

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Microbial

    Not on this COA

    Bioburden / microbial limits testing.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    ≤ 0.05 EU/mL (both replicates)

  • Sterility

    Not on this COA

    Sterility testing where applicable.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Residual solvent / water

    Not on this COA

    Residual solvents or water content limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing

Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    99.785% purity by HPLC is within normal range for research-grade peptides

  • Mass spec confirmation present

    LCMS/MS data shows expected molecular ion peaks for GHK-Cu

  • Endotoxin testing performed

    Duplicate endotoxin testing per USP <85> guidelines, both replicates pass at ≤ 0.05 EU/mL

  • Generic lot number

    Lot number '0001' is very generic and may indicate limited batch tracking

  • Lab verification needed

    Freedom Diagnostics is not a widely recognized third-party testing lab; independent verification of lab credentials recommended

  • Two separate accession numbers

    Document contains two COAs (2511190041 for purity/identity, 2511190042 for endotoxin) for same lot 0001, which is unusual but may reflect lab workflow

  • Limited testing scope

    No heavy metals, microbial, sterility, or residual solvent testing reported

  • Dates are reasonable

    Received 2025-11-19, reported 2025-11-21 (2-day turnaround is plausible)

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.