Public COA audit

GHK-Cu

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
93%
Panels
2/7
Purity (printed)
99.6%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), and 2 soft concerns. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
29G78QT
Identity method
FTIR (USP <197A>)
Sample date
2026-03-04
Issue date
2026-03-07

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    FTIR sample spectrum confirms the presence of GHK-Cu with addition of excipient(s)/fillers

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.6%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High HPLC purity confirmed

    99.6% purity by HPLC (USP <621>) with supporting chromatogram showing dominant peak at 3.792 min (35779.7 mAU*s) and minor impurities at 4.071 and 4.194 min

  • Identity confirmed by FTIR

    FTIR spectrum confirms GHK-Cu presence with excipients/fillers, consistent with formulated peptide product

  • Batch information complete

    Lot 29G78QT with BT Sample ID 005000039112634, labeled content 100 mg, actual mass 264.7 mg, potency 111.2 mg (111.2%)

  • Testing timeline appropriate

    Tested 2026-03-04, issued 2026-03-07 (3-day turnaround)

  • Testing lab identified

    BTLabs, West Palm Beach FL, with contact information and dual scientist signatures (Andrea Castro AS, Verna Zheng AS)

  • Limited scope testing

    Document explicitly states it does not provide information on particulate matter, microbial contamination or presence of endotoxins. This is a purity/identity-focused report only

  • Professional presentation

    Dual-branded document (BTLabs testing lab + Finnrick customer), includes visual sample description, FTIR and HPLC chromatograms, digital signatures with metadata, verification URL

  • Potency slightly over specification

    Potency result 111.2% exceeds the 90-110% specification range by 1.2%, though this is a minor deviation and may be within measurement uncertainty

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.