Public COA audit

GHK-Cu

Audited July 29, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
83%
Panels
2/7
Purity (printed)
99.6%

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
29G78QT
Identity method
FTIR (USP <197A>) and HPLC (USP <621>)
Sample date
2026-03-04
Issue date
2026-03-07

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    FTIR sample spectrum confirms the presence of GHK-Cu with addition of excipient(s)/fillers

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.6%

  • Heavy metals

    Not on this COA

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Microbial

    Not on this COA

    Bioburden / microbial limits testing.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Endotoxin

    Not on this COA · core

    LAL or chromogenic endotoxin assay.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Sterility

    Not on this COA

    Sterility testing where applicable.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Residual solvent / water

    Not on this COA

    Residual solvents or water content limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing

Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High HPLC purity

    99.6% purity by HPLC is excellent and within normal range for research-grade peptides

  • Identity confirmed

    FTIR spectrum confirms GHK-Cu presence with excipients/fillers noted

  • Potency exceeds specification

    Potency result is 111.2% (111.2 mg), which exceeds the upper specification limit of 110% of labeled 100 mg

  • Batch number present

    Lot Number 29G78QT clearly documented

  • Dates present and reasonable

    Sample tested 2026-03-04, report issued 2026-03-07 (3-day turnaround)

  • Dual lab presentation

    Document shows both BTLabs branding and Finnrick Testing Certificate header with different verification URLs (btlabtesting.com vs finnrick.com/verify), suggesting possible reseller/intermediary relationship

  • Limited testing scope

    Testing purpose explicitly states it does NOT provide information on particulate matter, microbial contamination, or endotoxins. No heavy metals, sterility, or residual solvent testing performed

  • Professional presentation

    Document includes digital signatures, FTIR spectrum, HPLC chromatogram, and detailed peak data

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.