Public COA audit
GHK-Cu
Audited September 5, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 92
- Confidence
- 93%
- Panels
- 2/7
- Purity (printed)
- 99.6%
Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), and 2 soft concerns. To improve: include identity, purity, and endotoxin at minimum.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- 29G78QT
- Identity method
- FTIR (USP <197A>)
- Sample date
- 2026-03-04
- Issue date
- 2026-03-07
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
FTIR sample spectrum confirms the presence of GHK-Cu with addition of excipient(s)/fillers
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.6%
Heavy metals
Not on this certificate file
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Not on this certificate file · core
LAL or chromogenic endotoxin assay.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Sterility
Not on this certificate file
Sterility testing where applicable.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High HPLC purity confirmed
99.6% purity by HPLC (USP <621>) with supporting chromatogram showing dominant peak at 3.792 min (35779.7 mAU*s) and minor impurities at 4.071 and 4.194 min
Identity confirmed by FTIR
FTIR spectrum confirms GHK-Cu presence with excipients/fillers, consistent with formulated peptide product
Batch information complete
Lot 29G78QT with BT Sample ID 005000039112634, labeled content 100 mg, actual mass 264.7 mg, potency 111.2 mg (111.2%)
Testing timeline appropriate
Tested 2026-03-04, issued 2026-03-07 (3-day turnaround)
Testing lab identified
BTLabs, West Palm Beach FL, with contact information and dual scientist signatures (Andrea Castro AS, Verna Zheng AS)
Limited scope testing
Document explicitly states it does not provide information on particulate matter, microbial contamination or presence of endotoxins. This is a purity/identity-focused report only
Professional presentation
Dual-branded document (BTLabs testing lab + Finnrick customer), includes visual sample description, FTIR and HPLC chromatograms, digital signatures with metadata, verification URL
Potency slightly over specification
Potency result 111.2% exceeds the 90-110% specification range by 1.2%, though this is a minor deviation and may be within measurement uncertainty
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.