Public COA audit

GHK-Cu

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
83%
Panels
3/7
Purity (printed)
99.9%

Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (3/7), 3 soft concerns, and notable note: "High purity confirmed". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
9mkr2fk
Identity method
HPLC-UV-MS
Sample date
2026-01-29
Issue date
2026-02-18

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 2 passed · 0 failed · 1 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    ID Confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    >99.9%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · result on file · core

    LAL or chromogenic endotoxin assay.

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    Chromatographic purity >99.9% by HPLC-UV/MS with supporting chromatogram showing single dominant peak at 0.63 min

  • Identity confirmed by mass spectrometry

    Mass spectrum matches reference standard for GHK-Cu (CAS 49557-75-7); molecular ion peaks visible in MS data

  • Batch/lot number present

    Lot 9mkr2fk clearly marked on certificate and vial images

  • Dates are valid and logical

    Sample received 2026-01-29, tested 2026-02-11, report issued 2026-02-18 - all dates are sequential and on or before 2026-09-05

  • Vendor/lab name inconsistency

    Document header shows 'Finnrick.com' and 'Finnrick Analytics' but footer and methods reference 'Krause Analytical LLC' - appears to be a reseller/white-label arrangement but creates confusion about actual testing lab

  • Methods described but results not shown

    Page 3 describes methods for endotoxin (LAL) and heavy metals (ICP-MS) testing, but no actual test results are provided in this certificate - this may be a purity-focused report with other panels tested separately

  • Limited testing scope

    This certificate only shows purity/identity/potency results; no microbial, sterility, residual solvent, or water content data present

  • Professional presentation

    Certificate includes vial photos, chromatogram, mass spectrum data, detailed methods summary, and signature from Laboratory Director Mark C. Krause

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.