Public COA audit

GHK-Cu

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
93%
Panels
3/7
Purity (printed)
99.64%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (3/7), and 2 soft concerns. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
yq5kpse
Identity method
HPLC-UV-MS
Sample date
2025-11-19
Issue date
2025-11-25

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    ID Confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.64%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    ND (< 1 EU/mL)

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High chromatographic purity

    99.64% purity by HPLC-UV/MS is excellent and typical for research-grade peptides

  • Identity confirmed by mass spectrometry

    Mass spectrum matches reference standard for GHK-Cu (CAS 49557-75-7); chromatogram and MS data provided on page 2

  • Batch/lot number present

    Lab # 130412, Test Certificate ID yq5kpse, Project 135501

  • Dates are consistent and valid

    Sample received 2025-11-19, testing 2025-11-23/25, report issued 2025-11-25 — all dates are logical and on or before 2026-09-05

  • Testing lab identified

    Krause Analytical LLC, 8127 Mesa Drive Suite B-206, Austin, TX 78759; signed by Mark C. Krause, Laboratory Director

  • Endotoxin testing performed

    Endotoxins not detected (< 1 EU/mL) by USP 86 LAL method

  • Heavy metals panel not performed

    Methods summary on page 3 describes USP/NF 233 ICP-MS for metals, but no results are reported in this certificate

  • Microbial and sterility panels not performed

    No microbial contamination or sterility testing results are included in this report

  • Professional formatting with supporting data

    Document includes chromatogram, mass spectrum comparison, methods summary, and verification URL; consistent branding for Finnrick/Krause Analytical

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.