Public COA audit

GHK-Cu

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
93%
Panels
3/7
Purity (printed)
99.7%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (3/7), and 2 soft concerns. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
CR-GCU100-2603-1
Identity method
FTIR (USP <197A>)
Sample date
2026-04-02
Issue date
2026-04-05

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    FTIR sample spectrum confirms the presence of GHK-Cu with addition of excipient(s)/fillers

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.7%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    12.2 EU/vial (limit: 40 EU/vial)

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High HPLC purity

    99.7% purity by HPLC (USP <621>) meets specification of ≥98%. This is normal for research-grade peptides.

  • FTIR identity confirmed

    FTIR spectrum confirms GHK-Cu identity with excipients/fillers present, consistent with formulated peptide product.

  • Endotoxin testing performed

    Separate endotoxin report (page 3, dated 4/10/2026) shows gel clot LAL test result of 12.2 EU/vial, passing the 40 EU/vial specification.

  • Lot number consistent

    Lot CR-GCU100-2603-1 appears on both purity/identity report and endotoxin report with matching visual descriptions.

  • BTLabs contact information

    Lab name, address (5730 Corporate Way, Suite 220, West Palm Beach, FL 33407), phone (561-625-0133), and website (https://btlabtesting.com) are provided.

  • Professional multi-page report

    Report includes detailed FTIR and HPLC chromatograms, QR code, signatures from two scientists (Andrea Castro and Verna Zheng), and consistent formatting across pages.

  • Potency variance across measurements

    HPLC potency shows three measurements: 113 mg (112.9%), 68.3 mg (68.3%), and 72.2 mg (72.3%). The first exceeds specification (90-110% of 100 mg), while the latter two are below. This may reflect sampling variability or inhomogeneous distribution in the vial.

  • Limited panel scope

    Testing purpose explicitly states this does not provide information on particulate matter or microbial contamination. Heavy metals, sterility, and residual solvents/water content not tested.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.