Public COA audit

GHK-Cu

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
88
Confidence
92%
Panels
3/7
Purity (printed)
99.86%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (3/7), and 2 soft concerns. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
CR-GHK100-0212-1
Identity method
HPLC with UV Detection Coupled with Mass Spectrometry
Sample date
2026-02-16
Issue date
2026-02-17

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    GHK-Cu confirmed by mass spectrometry with [M+2H]2+ 171.05 and [M+H]+ 341.05

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.86% average (Vial 1: 99.84%, Vial 2: 99.90%, Vial 3: 99.85%)

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    ≤ 0.05 EU/mL (both replicates)

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed across three vials

    Average purity 99.86% with consistent results across all three vials (99.84%, 99.90%, 99.85%). This is normal for research-grade peptides.

  • Mass spectrometry confirmation provided

    Mass spec data shows expected molecular ion peaks for GHK-Cu: [M+2H]2+ at 171.05 and [M+H]+ at 341.05, with HPLC chromatogram showing single major peak.

  • Endotoxin testing completed

    Two replicates both passed with results ≤ 0.05 EU/mL, meeting typical research-grade thresholds.

  • Batch information complete

    Lot number CR-GHK100-0212-1 clearly stated with net peptide content measured for three vials.

  • Dates are current and logical

    Received 02/16/2026, reported 02/17/2026 - one-day turnaround is reasonable for routine testing.

  • Lab identification present

    Freedom Diagnostics with verification URL and contact email provided. Signed by Stephen Schmidt, Principal Chemist.

  • Limited testing scope

    Heavy metals, microbial contamination, sterility, and residual solvents/water content not tested. This is common for basic research-grade COAs but limits comprehensive quality assessment.

  • Minor presentation inconsistencies

    Some formatting appears basic (e.g., 'TEST TEST TEST' placeholder text visible at top), though core data is clearly presented.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.