Public COA audit

Epithalon

Audited September 5, 2026

Incomplete documentation

Missing panels or key metadata — not enough evidence to treat this as a full certificate.

Legitimacy
45
Confidence
82%
Panels
1/7

Scored poorly because the file is incomplete or not a full COA, limited panel coverage (1/7), 3 critical findings, and notable note: "Endotoxin-only report". To improve: upload the full certificate (or the matching sibling purity/endotoxin report) and include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
DPS-9542380
Issue date
2026-08-22

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

1 of 7 present · 1 passed · 0 failed · 0 reported · 6 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Not on this certificate file · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Purity

    Not on this certificate file · core

    Reported purity percentage for the analyte.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    <0.05 EU/mL

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • Endotoxin-only report

    This COA only contains endotoxin testing results. No purity (HPLC), identity (MS), heavy metals, microbial, sterility, or residual solvent/water panels are present. This appears to be a supplemental endotoxin-specific report rather than a comprehensive COA.

  • No purity data

    No HPLC or other purity measurement is provided. Cannot assess compound purity from this document.

  • No identity confirmation

    No mass spectrometry, NMR, or other identity confirmation method is documented. Only compound name and CAS number are listed.

  • No sample date

    Analysis date is provided (08/22/2026) but no sample collection or receipt date is documented.

  • Lot number present

    Lot number DPS-9542380 is clearly documented.

  • Lab identification

    Testing lab Horizon Analytical is identified with contact information and verification URL. Signed by Aleksey Yevtodiyenko PhD.

  • Endotoxin testing present

    Endotoxin test shows <0.05 EU/mL with Pass result. This is the only analytical panel in this report.

  • Limited scope document

    This appears to be a supplemental or partial COA focused solely on endotoxin testing. A complete COA would typically include purity and identity panels at minimum.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.