Public COA audit
Epithalon · Epithalon 10mg
Audited September 5, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 92
- Confidence
- 93%
- Panels
- 5/7
- Purity (printed)
- 99.8%
Scored high because the document is mostly consistent but carries soft concerns, broad panel coverage (5/7), and 1 soft concern.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- EPIT10-0528
- Identity method
- MALDI-MS
- Sample date
- 2026-06-01
- Issue date
- 2026-06-17
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
5 of 7 present · 5 passed · 0 failed · 0 reported · 2 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
Epithalon
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.8%
Heavy metals
Tested · passed
Lead, arsenic, cadmium, mercury, or similar limits.
<0.01ppm
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Tested · passed · core
LAL or chromogenic endotoxin assay.
<0.05 EU/mL
Sterility
Tested · passed
Sterility testing where applicable.
Not Detected
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High purity confirmed
99.8% purity by RP-HPLC with clean chromatogram showing single major peak at 1.632 min retention time
Identity confirmed
MALDI-MS confirms Epithalon identity with [M+H]+ ion at 390.3 m/z matching expected MW
Comprehensive testing
Document includes identity, purity, content quantitation (10.13 mg), sterility, heavy metals, and endotoxin panels
Batch information complete
Lot number EPIT10-0528 clearly stated with vendor American Peptides
Dates valid
Sample received June 1, 2026; COA issued June 17, 2026 (both on or before current date 2026-09-05)
Lab identification present
Bioviridian lab with verification URL and QR code provided; signed by Shane Straight, M.S., Principal Chemist
Professional presentation
Well-formatted document with clear tables, chromatogram, mass spectrum, and verification code COA4850
Microbial panel absent
No microbial contamination testing (e.g., total aerobic count, yeast/mold) reported; only sterility testing present
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.