Public COA audit

Epitalon

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
95
Confidence
95%
Panels
5/7
Purity (printed)
97.98%

Scored high because the document is mostly consistent but carries soft concerns, broad panel coverage (5/7), and 1 soft concern.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
CR-EPTH-10MG-2606-1
Identity method
HPLC-RTM
Sample date
2026-06-13
Issue date
2026-06-27

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

5 of 7 present · 5 passed · 0 failed · 0 reported · 2 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    Confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    97.98%

  • Heavy metals

    Tested · passed

    Lead, arsenic, cadmium, mercury, or similar limits.

    All Not Detected (As, Cd, Cr, Hg, Pb)

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    0.053 EU/mL

  • Sterility

    Tested · passed

    Sterility testing where applicable.

    No Growth

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity with conformity testing

    97.98% purity confirmed across 3 samples (mean 97.87%, std dev 0.1158%), with HPLC chromatogram provided. This is normal for research peptides.

  • Identity confirmed by HPLC-RTM

    Epitalon confirmed by chromatographic retention time comparison with reference standard.

  • Batch information complete

    Lot CR-EPTH-10MG-2606-1, COA-2026-VZPTWE, Accession ACC-2026-5025.

  • Dates consistent and valid

    Received 2026-06-13, analyzed and issued 2026-06-27. All dates are on or before 2026-09-05.

  • ISO/IEC 17025 accredited lab

    ILS Laboratories, San Diego, CA. ISO/IEC 17025 accredited. Verification URL and access code provided.

  • Comprehensive testing panel

    Identity, purity, heavy metals (ICP-MS), sterility (PCR), endotoxin (USP <85>), and fentanyl screen all performed and passed.

  • Microbial and residual solvent panels not present

    No microbial contamination panel (e.g., total aerobic count, yeast/mold) or residual solvent/water content testing visible in this report. This is not uncommon for research-grade peptide COAs.

  • Professional formatting and documentation

    Well-structured 2-page report with detailed methodology notes, conformity testing results, chromatogram, and signature.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.