Public COA audit

DSIP

Audited September 5, 2026

Consistent with a legitimate COA

Document structure and test panels align with what we expect from authentic lab reports.

Legitimacy
95
Confidence
95%
Panels
5/7
Purity (printed)
99.89%

Scored high because document structure and panels look consistent with authentic lab output and broad panel coverage (5/7).

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
CR-DSIP10-2607-White
Identity method
HPLC-RTM
Sample date
2026-07-19
Issue date
2026-07-31

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

5 of 7 present · 4 passed · 0 failed · 1 reported · 2 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    DSIP Confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.89%

  • Heavy metals

    Tested · passed

    Lead, arsenic, cadmium, mercury, or similar limits.

    As: 0.0651 ppm, Cd: 0.191 ppm, Pb: 0.65198 ppm, Hg: 0.31981 ppm, Cr: 0.618 ppm

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · result on file · core

    LAL or chromogenic endotoxin assay.

    0.094 EU/mL

  • Sterility

    Tested · passed

    Sterility testing where applicable.

    No Growth

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity with conformity testing

    99.89% purity confirmed across three conformity samples (mean 99.90%, std dev 0.0249%), demonstrating excellent batch consistency

  • Identity confirmed by HPLC-RTM

    DSIP identity confirmed by chromatographic retention time comparison with reference standard

  • Clear batch identification

    Lot number CR-DSIP10-2607-White clearly stated with net peptide content 10.53 mg (labeled 10 mg)

  • Dates consistent and valid

    Sample received 2026-07-19, analyzed and issued 2026-07-31, all dates are valid and sequential

  • ISO/IEC 17025 accredited lab

    ILS Laboratories claims ISO/IEC 17025 accreditation with complete contact information and verification URL provided

  • Comprehensive testing panel

    Full QC panel includes HPLC purity/identity, heavy metals (ICP-MS), sterility (PCR), and endotoxin (USP <85>). Microbial and residual solvent panels not present but not required for all peptide products

  • Endotoxin testing present

    Endotoxin tested per USP <85> kinetic turbidimetric method with result 0.094 EU/mL reported as quantitative value below commonly referenced thresholds

  • Professional presentation

    Well-formatted two-page report with chromatogram, conformity data table, detailed methodology notes, QR code verification, and lab director signature

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.