Public COA audit
Vilon · Vilon 20mg
Audited September 5, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 92
- Confidence
- 93%
- Panels
- 5/7
- Purity (printed)
- 99.9%
Scored high because the document is mostly consistent but carries soft concerns, broad panel coverage (5/7), and 1 soft concern.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- VILON20-0528
- Identity method
- MALDI-MS
- Sample date
- 2026-06-01
- Issue date
- 2026-06-17
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
5 of 7 present · 5 passed · 0 failed · 0 reported · 2 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
Vilon confirmed
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.9%
Heavy metals
Tested · passed
Lead, arsenic, cadmium, mercury, or similar limits.
<0.01ppm
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Tested · passed · core
LAL or chromogenic endotoxin assay.
<0.05 EU/mL
Sterility
Tested · passed
Sterility testing where applicable.
Not Detected
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High purity confirmed
99.9% purity by RP-HPLC with clean chromatogram showing single major peak at 1.563 min retention time
Identity confirmed
MALDI-MS shows [M+H]+ at 275.219, matching expected MW of 275.3 g/mol for Vilon
Comprehensive testing
Document includes identity, purity, content quantitation (20.13 mg), sterility, heavy metals, and endotoxin panels
Batch information complete
Lot number VILON20-0528 clearly stated with vendor American Peptides
Dates appropriate
Sample received June 1, 2026; COA issued June 17, 2026 (16-day turnaround is reasonable)
Lab credentials present
Bioviridian lab with verification URL, QR code, signature by Shane Straight M.S. (Principal Chemist), and web verification code COA4861
Professional presentation
Clean layout with product photo, chromatogram, mass spectrum, and all required analytical methods clearly stated
Microbial panel absent
No microbial contamination testing (e.g. total aerobic count, yeast/mold) reported; only sterility test present
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.