Public COA audit

Prostamax · Prostamax 10mg

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
93%
Panels
3/7
Purity (printed)
99.9%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (3/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
PROS20-0318
Identity method
MALDI-MS
Sample date
2026-03-26
Issue date
2026-04-03

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    Prostamax confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.9%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    < 0.05 EU/mL

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    99.9% purity by RP-HPLC at 214 nm with clean chromatogram showing single major peak at 2.275 min retention time

  • Identity confirmed by mass spectrometry

    MALDI-MS confirms molecular identity with [M+H]+ ion at 487.5 m/z matching expected MW of 487.5 g/mol

  • Endotoxin testing included

    Endotoxin level < 0.05 EU/mL, marked as PASS

  • Batch number present

    Lot PROS20-0318 clearly identified

  • Dates are logical and current

    Sample received March 26, 2026; COA issued April 3, 2026 (8 days turnaround)

  • Testing lab identified with verification

    Bioviridian lab with web verification code COA3398 and URL provided; signed by Shane Straight, M.S., Principal Chemist

  • Professional presentation

    Well-formatted document with clear analytical data, chromatogram, mass spectrum, and QR code for verification

  • Limited testing scope

    Heavy metals, microbial, sterility, and residual solvent/water panels not included in this report

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.