Public COA audit

Ipamorelin · CJC-1295

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
85%
Panels
3/7
Purity (printed)
99.9%

Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (3/7), 2 soft concerns, and notable note: "High purity results". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
CR-CJIP10-260101
Identity method
HPLC with UV Detection Coupled with Mass Spectrometry (LCMS/MS)
Sample date
2026-01-08
Issue date
2026-01-11

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    Ipamorelin [M+H]+ 712.08, CJC-1295 [M+4H]4+ 942.53 and [M+3H]3+ 1123.08

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    Vial 1: 99.93%, Vial 2: 99.84%, Vial 3: 99.92%, Average: 99.90%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    Replicate 1: ≤ 0.05 EU/mL, Replicate 2: ≤ 0.05 EU/mL

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity results

    Average purity of 99.90% across three vials is excellent and consistent with high-quality research peptides. Individual vial purities range from 99.84% to 99.93%.

  • Mass spectrometry confirmation

    Both peptides identified by mass spec with appropriate m/z values. Chromatogram shows clear separation of the two compounds.

  • Endotoxin testing performed

    Endotoxin testing shows passing results (≤ 0.05 EU/mL) in duplicate, which is appropriate for injectable research compounds.

  • Limited lab verification information

    Freedom Diagnostics is mentioned with a website (FreedomDiagnosticsTesting.com) and email, but no physical address, accreditation information, or independent verification details are provided.

  • Limited testing scope

    COA only includes purity, identity, and endotoxin testing. Missing heavy metals, microbial contamination, sterility, and residual solvent/water content panels that are common in comprehensive peptide testing.

  • Batch and accession numbers present

    Clear lot number (CR-CJIP10-260101) and accession number (2601080302) with search code provided for verification.

  • Appropriate date timeline

    Received date 01/08/2026 and reported date 1/11/2026 show a 3-day turnaround, which is reasonable for this testing scope.

  • Professional presentation

    Document includes chromatogram, mass spectrum, product photos, and clear data tables. Signed by Principal Chemist Stephen Schmidt with appropriate research-use-only disclaimer.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.