Public COA audit
CJC-1295 · CJC-1295 10mg No DAC
Audited July 28, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 62
- Confidence
- 75%
- Panels
- 2/7
- Purity (printed)
- 99.817%
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- 665394
- Identity method
- HPLC with UV Detection Coupled with Mass Spectrometry
- Sample date
- 2026-04-06
- Issue date
- 2026-04-07
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
CJC-1295 confirmed via mass spectrometry
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.817%
Heavy metals
Not on this COA
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Microbial
Not on this COA
Bioburden / microbial limits testing.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Endotoxin
Not on this COA · core
LAL or chromogenic endotoxin assay.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Sterility
Not on this COA
Sterility testing where applicable.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Residual solvent / water
Not on this COA
Residual solvents or water content limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing
Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High purity confirmed
HPLC purity of 99.817% with clean chromatogram showing single major peak at retention time ~10.0 min. This is normal for research-grade peptides.
Mass spectrometry confirmation
Mass spectrum shows expected charge states for CJC-1295: [M+5H]5+, [M+6H]6+, [M+4H]4+, [M+3H]3+ with m/z values consistent with the peptide.
Lab verification unclear
Freedom Diagnostics is listed with website FreedomDiagnosticsTesting.com and email [email protected]. Independent verification of this lab's accreditation status could not be performed from the document alone.
Limited testing scope
COA only includes identity and purity testing. No heavy metals, microbial, endotoxin, sterility, or residual solvent/water testing reported. This is common for basic peptide COAs but limits comprehensive quality assessment.
Batch information present
Lot number 665394 clearly stated with net peptide content of 11.81 mg.
Dates within normal range
Received 2026-04-06, reported 2026-04-07 (one-day turnaround). Both dates are before today (2026-07-28) and represent reasonable testing timeline.
Basic presentation
Document has simple formatting with stock product photos. While not necessarily indicative of fraud, professional testing labs typically use more detailed technical documentation.
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.