Public COA audit
CJC-1295 · CJC-1295 10mg No DAC
Audited September 5, 2026
Multiple signals on this document conflict with known lab formats or verification patterns.
- Legitimacy
- 15
- Confidence
- 92%
- Panels
- 2/7
- Purity (printed)
- 99.817%
Scored poorly because audit signals point to fabrication or reused paperwork, limited panel coverage (2/7), 3 critical findings, and notable note: "Non-existent testing laboratory". To improve: replace this file with an original lab certificate that verifies on the lab portal and include identity, purity, and endotoxin at minimum.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- 665394
- Identity method
- HPLC with UV Detection Coupled with Mass Spectrometry
- Sample date
- 2026-04-06
- Issue date
- 2026-04-07
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
CJC-1295 confirmed
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.817%
Heavy metals
Not on this certificate file
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Not on this certificate file · core
LAL or chromogenic endotoxin assay.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Sterility
Not on this certificate file
Sterility testing where applicable.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
Non-existent testing laboratory
Freedom Diagnostics and FreedomDiagnosticsTesting.com do not correspond to any known accredited peptide testing laboratory. No online presence, accreditation records, or independent verification available for this entity.
Unprofessional document quality
Document exhibits multiple formatting irregularities: inconsistent spacing, amateur layout, generic stock imagery of vials, and overall presentation inconsistent with legitimate analytical laboratory reports.
Unverifiable contact information
Contact email [email protected] and website cannot be independently verified. Legitimate testing labs provide verifiable physical addresses, phone numbers, and accreditation details.
Limited testing scope
Only identity and purity testing performed. No heavy metals, microbial, endotoxin, sterility, or residual solvent testing. While not automatically disqualifying, this is a minimal testing panel.
Generic product photography
Document includes stock-style product vial images rather than actual analytical data visualization or laboratory-specific documentation, which is unusual for professional COAs.
Dates within acceptable range
Received date 2026-04-06 and reported date 2026-04-07 are both before today (2026-09-05) and show reasonable one-day turnaround.
High purity reported
99.817% purity is high but within normal range for research-grade peptides. Not a red flag by itself.
Mass spec data included
Document shows mass spectrometry peaks with m/z values ([M+5H]5+, [M+6H]6+, [M+4H]4+, [M+3H]3+) consistent with peptide analysis.
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.