Public COA audit

CJC-1295

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
88
Confidence
92%
Panels
2/7
Purity (printed)
99.5%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), and 2 soft concerns. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
H5ZYV53
Identity method
FTIR (USP <197A>)
Sample date
2026-04-30
Issue date
2026-05-04

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    FTIR sample spectrum confirms the presence of CJC-1295 with addition of excipient(s)/fillers

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.5%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High HPLC purity

    99.5% purity by HPLC is excellent and normal for research-grade peptides

  • Identity confirmed

    FTIR spectrum confirms CJC-1295 presence with excipients/fillers noted

  • Batch information complete

    Lot H5ZYV53, BT Sample ID 005000039803395, labeled content 5 mg

  • Dates are valid

    Tested 2026-04-30, issued 2026-05-04 (both on or before today 2026-09-05)

  • Testing lab identified

    BTLabs, West Palm Beach FL, with contact info and dual scientist signatures (Andrea Castro, Verna Zheng)

  • Limited scope testing

    This COA explicitly states it does NOT provide information on particulate matter, microbial contamination, or endotoxins. Only identity/purity/potency testing performed. Heavy metals, sterility, and residual solvents also not tested in this report.

  • Potency exceeds specification

    Measured potency 6.5 mg (130.4%) exceeds the 90-110% specification range for labeled 5 mg content, though this may reflect overfill or measurement variability

  • Professional presentation

    Document includes FTIR spectrum, HPLC chromatogram, detailed test methods (USP references), verification URL, and digital signatures

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.