Public COA audit

Ipamorelin · CJC-1295 no DAC

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
88%
Panels
2/7
Purity (printed)
99.13%

Scored moderately because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), 4 soft concerns, and notable note: "High purity confirmed". To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
B-9043831-P
Identity method
UPLC/MS
Issue date
2026-06-16

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    Ipamorelin confirmed by UPLC/MS

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.13%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    Ipamorelin 99.13% and CJC-1295 no DAC 99.28% purity by UPLC, both exceeding ≥98% specification. High purity is normal for research peptides.

  • Identity confirmed by UPLC/MS

    Both compounds confirmed by UPLC/MS with mass spectrometry data and chromatograms provided. PubChem CIDs referenced (9831659 for Ipamorelin, 91976840 for CJC-1295 no DAC).

  • Same lot number for two different compounds

    Both Ipamorelin and CJC-1295 no DAC share lot number B-9043831-P. This is unusual unless this is a blend/stack product, which is not indicated. Typically each compound receives a unique lot identifier.

  • Analysis date precedes lab received date

    Analysis Conducted: 06/16/2026, but Lab Received Date: 06/21/2026. The sample was analyzed 5 days before the lab received it, which is logically impossible.

  • Lab verification not independently confirmed

    Horizon Analytical is listed with [email protected] and horizonanalytical.com for verification. Independent verification of this lab's existence and accreditation was not performed in this audit.

  • Purity/identity report file

    This certificate file looks like a purity/identity report. Many vendors publish a separate endotoxin report for the same lot — missing endotoxin on this file alone does not prove the lot was never tested.

  • Professional presentation

    Document includes QR codes for validation, chromatograms, mass spectra, chemist signature, and standard COA formatting elements.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.