Public COA audit

Cagrinitide Amylin Analog

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
95%
Panels
1/7

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (1/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
6-3-45951
Sample date
2025-11-19
Issue date
2025-11-19

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

1 of 7 present · 1 passed · 0 failed · 0 reported · 6 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Not on this certificate file · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Purity

    Not on this certificate file · core

    Reported purity percentage for the analyte.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    < 0.050 EU/mL

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • Endotoxin testing performed

    Chromogenic LAL assay performed using Endosafe-PTS system. Result < 0.050 EU/mL passes specification of < 0.25 EU/mL. Spike recovery 76% (Pass), test suitability Pass.

  • Professional testing lab

    BioRegen is a recognized independent testing laboratory with verification system (QR code, Report ID: BL-ENDO-251911-166, Validation Key: BIOLABS2010).

  • Batch information present

    Sample lot number 6-3-45951 clearly documented. Sample tested: Cagrinitide Amylin Analog from Biolongevity Labs.

  • Test date documented

    Test performed and signed on 11/19/2025, which is within normal timeframe (before current date 2026-09-05).

  • Limited scope report

    This is an endotoxin-specific report only. Identity, purity (HPLC), heavy metals, microbial, sterility, and residual solvent panels are not included in this document. This is normal for split testing where different analyses are reported separately.

  • Professional formatting

    Report includes proper headers, analyst signature (MARIN), instrument details (Endosafe nexgen-PTS SN: 25201216), reagent information with lot numbers and calibration codes, and interpretation section.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.