Public COA audit
BPC-157 · Wolverine
Audited September 5, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 92
- Confidence
- 93%
- Panels
- 4/7
- Purity (printed)
- 99.2%
Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (4/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- hxvm3e6
- Identity method
- HPLC-UV-MS with Mass Spectral Match
- Sample date
- 2026-05-05
- Issue date
- 2026-05-19
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
4 of 7 present · 2 passed · 0 failed · 2 reported · 3 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
ID Confirmed
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.2%
Heavy metals
Tested · result on file
Lead, arsenic, cadmium, mercury, or similar limits.
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Tested · result on file · core
LAL or chromogenic endotoxin assay.
Sterility
Not on this certificate file
Sterility testing where applicable.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High chromatographic purity
99.2% purity by HPLC-UV/MS is excellent and normal for research-grade peptides
Mass spectral identity confirmed
BPC-157 identity confirmed by mass spectral match; Thymosin β4 correctly identified as not detected (ND)
Batch/lot number present
Lot hxvm3e6 clearly stated with 4.94 mg BPC-157 (49.4% of 10 mg label claim)
Dates are valid and consistent
Sample received 2026-05-05, tested 2026-05-09, report issued 2026-05-19 — all dates are logical and on or before today (2026-09-05)
Lab information complete
Krause Analytical LLC (doing business as Finnrick Analytics), 8127 Mesa Drive Suite B-206, Austin, TX 78759. Lab director Mark C. Krause signature present. Verification URL provided: https://finnrick.com/verify
Endotoxin and heavy metals methods documented
Page 4 Methods Summary describes LAL endotoxin testing (USP/NF 86) and ICP-MS heavy metals testing (USP/NF 233). Results not shown on this report but methods are documented.
Endotoxin and metals results not displayed
Methods summary indicates endotoxin (LAL) and heavy metals (ICP-MS) testing are performed, but numerical results are not shown on this COA. This may be a purity/identity-scoped report with separate safety panel reports.
Professional formatting with chromatogram and mass spectrum
Document includes HPLC chromatogram (page 2) and mass spectrum (page 3) consistent with legitimate analytical lab reports. Watermark 'FINNRICK' present throughout.
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.