Public COA audit

BPC-157 · BPC 157

Audited July 29, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
72
Confidence
85%
Panels
3/7
Purity (printed)
99.463%

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
0006
Identity method
HPLC with UV Detection Coupled with Mass Spectrometry (LCMS/MS)
Sample date
2025-11-19
Issue date
2025-11-21

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 3 passed · 0 failed · 0 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    BPC-157 confirmed via mass spec [M+2H]2+ 710.38

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.463%

  • Heavy metals

    Not on this COA

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Microbial

    Not on this COA

    Bioburden / microbial limits testing.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    ≤ 0.05 EU/mL (both replicates)

  • Sterility

    Not on this COA

    Sterility testing where applicable.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

  • Residual solvent / water

    Not on this COA

    Residual solvents or water content limits.

    No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing

Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    99.463% purity by HPLC is within normal range for research-grade peptides

  • Mass spec confirmation present

    LCMS/MS data shows [M+2H]2+ ion at 710.38 m/z with chromatogram showing single major peak at ~4.5 min retention time

  • Batch/lot number present

    Lot 0006 clearly stated

  • Lab verification unclear

    Freedom Diagnostics claims USA operation with searchable verification URL, but independent verification of lab accreditation/credentials not possible from document alone

  • Limited testing scope

    Only identity, purity, and endotoxin panels present. Missing heavy metals, microbial, sterility, and residual solvent/water testing common in comprehensive COAs

  • Two separate accession numbers

    Document contains two COAs (2511190027 for purity/identity, 2511190028 for endotoxin) for same lot 0006, same client, same dates. This split-testing approach is unusual but not necessarily illegitimate

  • Professional presentation

    Document includes lab branding, signatory (Stephen Schmidt, Principal Chemist), appropriate disclaimers, and product photo

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.