Public COA audit
BPC-157 · Thymosin Beta-4
Audited July 29, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 72
- Confidence
- 85%
- Panels
- 2/7
- Purity (printed)
- 99.935%
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- N/A
- Identity method
- HPLC with UV Detection Coupled with Mass Spectrometry
- Sample date
- 2026-02-13
- Issue date
- 2026-02-16
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
BPC-157/Thymosin Beta-4 confirmed
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.935%
Heavy metals
Not on this COA
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Microbial
Not on this COA
Bioburden / microbial limits testing.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Endotoxin
Not on this COA · core
LAL or chromogenic endotoxin assay.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Sterility
Not on this COA
Sterility testing where applicable.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Residual solvent / water
Not on this COA
Residual solvents or water content limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing
Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High purity confirmed
99.935% purity by HPLC is within normal range for research-grade peptides
Identity confirmed by MS
Mass spectrometry data shows expected molecular ion peaks for BPC-157 and TB4
No lot/batch number provided
Lot field shows 'N/A' which limits traceability for quality control purposes
Dates are reasonable
Received 02/13/2026, reported 02/16/2026 - 3-day turnaround is plausible
Limited lab verification
Freedom Diagnostics appears to be a peptide testing service, but independent verification of accreditation status is recommended
Limited testing scope
Only identity and purity panels performed; no heavy metals, microbial, endotoxin, sterility, or solvent testing
Professional presentation
Document includes chromatogram, mass spectrum, product photo, and proper disclaimers
Research-only disclaimer present
COA explicitly states product is for research use only and not approved for human/veterinary use
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.