Public COA audit

BPC-157

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
93%
Panels
4/7
Purity (printed)
99.78%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (4/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
xzgt3gk
Identity method
HPLC-UV-MS
Sample date
2026-01-29
Issue date
2026-02-18

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

4 of 7 present · 2 passed · 0 failed · 2 reported · 3 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    ID Confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.78%

  • Heavy metals

    Tested · result on file

    Lead, arsenic, cadmium, mercury, or similar limits.

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · result on file · core

    LAL or chromogenic endotoxin assay.

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High HPLC purity

    99.78% chromatographic purity by HPLC-UV/MS, which is normal for research-grade peptides

  • Identity confirmed

    Mass spectrum matched authentic BPC-157 standard; CAS 137525-51-0 provided

  • Batch/lot documented

    Lot xzgt3gk clearly printed; 8.26 mg recovered (82.6% of 10 mg label claim)

  • Dates valid

    Sample received 2026-01-29, report issued 2026-02-18, testing on 2026-02-11 — all dates are consistent and on or before 2026-09-05

  • Lab identified

    Krause Analytical LLC, 8127 Mesa Drive Suite B-206, Austin, TX 78759; signed by Mark C. Krause, Laboratory Director

  • Methods summary provided

    Page 3 documents USP/NF methods for purity/potency/identification (621), endotoxins (85), and metals (233); chromatogram and mass spectrum included on page 2

  • Endotoxin/metals results not shown

    Methods summary indicates endotoxin (LAL) and heavy metals (ICP-MS) testing protocols exist, but no numerical results or pass/fail are printed on this certificate

  • Professional formatting

    Multi-page PDF with Finnrick/Krause Analytical branding, verification URL (https://finnrick.com/verify), and standard COA layout

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.