Public COA audit

BPC-157

Audited July 28, 2026

Incomplete documentation

Missing panels or key metadata — not enough evidence to treat this as a full certificate.

Legitimacy
45
Confidence
82%
Panels
0/7

Scored poorly because the file is incomplete or not a full COA, limited panel coverage (0/7), 3 critical findings, and notable note: "Only assay test present". To improve: upload the full certificate (or the matching sibling purity/endotoxin report) and include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
N260710-001
Issue date
2026-07-17

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

0 of 7 present · 0 passed · 0 failed · 0 reported · 7 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Not on this certificate file · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Purity

    Not on this certificate file · core

    Reported purity percentage for the analyte.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • Only assay test present

    COA contains only a single HPLC assay test (10.7 mg vs 10 mg specification). No identity confirmation (MS, NMR), no purity analysis (HPLC %), no safety panels (heavy metals, microbial, endotoxin). This is insufficient for peptide quality verification.

  • No purity data

    Document shows only mass/assay result (10.7 mg), not purity percentage. Standard peptide COAs require HPLC purity analysis showing percentage purity.

  • No identity confirmation

    No mass spectrometry, NMR, or other identity confirmation method present. Cannot verify the compound is actually BPC-157.

  • Lab verification unclear

    Qalitex Inc. claims ISO/IEC 17025:2017 accreditation (AGS-US050824-1) but no verification URL or QR code destination provided. Accreditation body 'AGS' format is non-standard for US labs (typically A2LA, ANAB, PJLA).

  • No sample/test dates

    Issue date present (2026-07-17) but no sample receipt date or testing date range provided. Cannot verify testing timeline.

  • Batch identifiers present

    Batch number N260710-001 and lot number SP26-BPV10 clearly stated.

  • Minimal content for 2-page document

    Page 2 is essentially blank except for header/footer. Unusual for a legitimate multi-page COA which typically includes chromatograms, detailed methods, or additional test results.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.