Public COA audit
BPC-157
Audited July 29, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 92
- Confidence
- 93%
- Panels
- 4/7
- Purity (printed)
- 99.9%
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- 4aquhzr
- Identity method
- HPLC-UV-MS
- Sample date
- 2026-04-16
- Issue date
- 2026-05-05
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
4 of 7 present · 2 passed · 0 failed · 2 reported · 3 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
ID Confirmed
Purity
Tested · passed · core
Reported purity percentage for the analyte.
>99.9%
Heavy metals
Tested · result on file
Lead, arsenic, cadmium, mercury, or similar limits.
Microbial
Not on this COA
Bioburden / microbial limits testing.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Endotoxin
Tested · result on file · core
LAL or chromogenic endotoxin assay.
Sterility
Not on this COA
Sterility testing where applicable.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
Residual solvent / water
Not on this COA
Residual solvents or water content limits.
No evidence for this panel. That lowers thoroughness — whether it matters depends on what you care about.
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing
Not on this certificate. Lowers thoroughness; you decide if that panel matters for your use case. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High purity confirmed
Chromatographic purity >99.9% by HPLC-UV/MS with clean chromatogram showing single dominant peak at 5.01 min
Identity confirmed
Mass spectral match confirmed by HPLC-UV-MS; mass spectrum shows expected m/z peaks including 711.3 (base peak), consistent with BPC-157
Potency within specification
9.78 mg recovered vs 10 mg label claim = 97.8% of label, within typical acceptable range
Batch/lot number present
Batch/Lot 4aquhzr clearly stated
Dates consistent
Sample received 2026-04-16, tested 2026-04-24, report issued 2026-05-05 - logical sequence
Lab information complete
Krause Analytical LLC, 8127 Mesa Drive Suite B-206 Austin, TX 78759; signed by Mark C. Krause, Laboratory Director
Verification URL provided
Certificate ID 4aquhzr with verification URL https://finnrick.com/verify
Methods summary included
Page 4 provides detailed methodology for purity/potency/identification (USP/NF 621), endotoxins (USP/NF 86), and metals (USP/NF 233)
Endotoxin and metals results not shown
Methods summary indicates endotoxin and heavy metals testing were performed, but numerical results are not displayed on page 1
Microbial and sterility testing absent
No microbial contamination or sterility testing panels present
Professional presentation
Multi-page report with chromatogram (page 2), mass spectrum (page 3), and methods (page 4); consistent branding and watermarking
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.