Public COA audit

Wolverine · BPC-157

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
93%
Panels
3/7
Purity (printed)
99.7%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (3/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
amsn7hu
Identity method
HPLC-UV-MS with Mass Spectral Match
Sample date
2026-05-22
Issue date
2026-06-02

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

3 of 7 present · 2 passed · 0 failed · 1 reported · 4 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    ID Confirmed (Mass Spectral Match for both BPC-157 and Thymosin β4)

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.7%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · result on file · core

    LAL or chromogenic endotoxin assay.

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High chromatographic purity

    99.7% purity by HPLC-UV/MS is excellent and typical for research-grade peptides

  • Dual peptide identity confirmed

    Mass spectral match confirmed for both BPC-157 (CAS 137525-51-0) and Thymosin β4 (CAS 77591-33-4) in combination product

  • Quantitative results exceed label claim

    BPC-157: 5.86 mg (117.1% of 5 mg claim), Thymosin β4: 6.21 mg (124.3% of 5 mg claim) - overfill is common practice

  • Batch/lot number present

    Lot amsn7hu clearly identified with verification URL

  • Dates are logical and recent

    Sample received 2026-05-22, tested 2026-05-30, report issued 2026-06-02 - all dates are sequential and on or before today (2026-09-05)

  • Established testing laboratory

    Krause Analytical LLC is a known third-party testing lab in Austin, TX with proper credentials and signature

  • Purity/identity-scoped report

    This document shows purity and identity testing only. Methods summary on page 4 describes endotoxin (LAL) and heavy metals (ICP-MS) procedures, but no results are shown in this file. This may be a split report where additional testing panels are documented separately.

  • Professional presentation with supporting data

    Includes HPLC chromatogram (page 2) and mass spectrum (page 3) supporting the reported results, plus detailed methods summary (page 4)

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.