Public COA audit

Wolverine · BPC-157

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
93%
Panels
5/7
Purity (printed)
99.9%

Scored high because the document is mostly consistent but carries soft concerns, broad panel coverage (5/7), and 1 soft concern.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
CR-BPTB20-2605-1
Identity method
HPLC-RTM (retention time match)
Sample date
2026-05-27
Issue date
2026-06-01

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

5 of 7 present · 4 passed · 0 failed · 1 reported · 2 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    BPC-157 + TB-500 Confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.90%

  • Heavy metals

    Tested · passed

    Lead, arsenic, cadmium, mercury, or similar limits.

    All Not Detected (As, Cd, Cr, Hg, Pb)

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Tested · result on file · core

    LAL or chromogenic endotoxin assay.

    NMT 0.05 EU/mL

  • Sterility

    Tested · passed

    Sterility testing where applicable.

    No Growth

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    99.90% purity by HPLC with conformity testing across two samples (99.85%, 99.90%, mean 99.88%). This is normal for research-grade peptides.

  • Identity confirmed

    Both BPC-157 and TB-500 components confirmed by HPLC retention time match. Chromatogram provided.

  • Batch information complete

    Lot CR-BPTB20-2605-1, COA COA-2026-Y6EVEO, Accession ACC-2026-3296. Net peptide content 21.14 mg (labeled 20 mg).

  • Dates consistent

    Received 2026-05-27, analyzed 2026-06-01, issued 2026-06-01. All dates are on or before 2026-09-05 (today) and logically sequenced.

  • Lab accreditation stated

    ILS Laboratories, San Diego CA, claims ISO/IEC 17025 accreditation. Verification URL and QR code provided.

  • Comprehensive testing

    Full QC panel includes purity, identity, heavy metals, sterility (PCR), endotoxin, and fentanyl screen. Microbial culture and residual solvent/water panels not present.

  • Endotoxin reported without pass/fail

    Endotoxin result is NMT 0.05 EU/mL with status 'Reported' rather than PASS/FAIL. The COA notes this is below commonly referenced thresholds and that no universal pass/fail applies to RUO products. This is acceptable for research-use materials but buyers should confirm suitability for their application.

  • Professional presentation

    Multi-page PDF with consistent branding, detailed methodology notes, conformity testing data, and chromatogram. Formatting is consistent with a legitimate analytical lab report.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.