Public COA audit
BPC-157 · TB-500
Audited September 5, 2026
Document structure and test panels align with what we expect from authentic lab reports.
- Legitimacy
- 95
- Confidence
- 95%
- Panels
- 5/7
- Purity (printed)
- 99.74%
Scored high because document structure and panels look consistent with authentic lab output and broad panel coverage (5/7).
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- CR-BPCTB10-2607-White
- Identity method
- HPLC-RTM (retention time matching)
- Sample date
- 2026-07-31
- Issue date
- 2026-08-03
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
5 of 7 present · 5 passed · 0 failed · 0 reported · 2 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
BPC-157 + TB-500 Confirmed
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.74%
Heavy metals
Tested · passed
Lead, arsenic, cadmium, mercury, or similar limits.
As: 0.619 ppm, Cd: 0.1561 ppm, Pb: 0.6651 ppm, Hg: 0.1619 ppm, Cr: 6.065 ppm
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Tested · passed · core
LAL or chromogenic endotoxin assay.
0.094 EU/mL
Sterility
Tested · passed
Sterility testing where applicable.
No Growth
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High purity confirmed with triplicate testing
Mean purity 99.73% across three independent HPLC runs (Dedicated V0: 99.72%, Conformity V1: 99.74%, Conformity V2: 99.73%) with low standard deviation (0.0082%), demonstrating excellent analytical reproducibility
Dual peptide identity confirmed
Both BPC-157 and TB-500 confirmed present by HPLC retention time matching against reference standards. Fentanyl screen negative (immunoassay, 50 ng/mL cutoff)
Complete batch traceability
Lot CR-BPCTB10-2607-White, COA-2026-954687, Accession ACC-2026-11208. Net blend content 10.65 mg (BPC-157: 5.43 mg, TB-500: 5.22 mg) exceeds labeled 10mg
Appropriate timeline
Received 2026-07-19, analyzed 2026-07-31, issued 2026-08-03. All dates are consistent and within normal laboratory turnaround time
ISO/IEC 17025 accredited laboratory
ILS Laboratories, San Diego CA, claims ISO/IEC 17025 accreditation. Verification URL and QR code provided (portal.ils-lab.com/verify/Cz9KLUvbkxlfMmt6, Access Code: CAFVK57P)
Comprehensive testing panel
Full QC panel includes purity (HPLC), identity (HPLC-RTM), heavy metals (ICP-MS), sterility (PCR), endotoxin (USP <85>), and fentanyl screening. Missing only microbial enumeration and residual solvents/water content
Heavy metals all pass
All five heavy metals tested (As, Cd, Pb, Hg, Cr) well below NMT limits per USP <233> methodology
Endotoxin well below limit
0.094 EU/mL vs. NMT 5 EU/mL specification (client-specified acceptance criteria)
Professional presentation
Well-formatted two-page report with HPLC chromatogram, detailed methodology notes, signature of Lab Director Dr. Greg Kalyuzhny, and clear pass/fail indicators throughout
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.