Public COA audit
BPC-157
Audited July 28, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 92
- Confidence
- 95%
- Panels
- 2/7
- Purity (printed)
- 98.8%
Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- COA-2026-C82/TP1
- Identity method
- HPLC-QTOF MS
- Sample date
- 2026-07-13
- Issue date
- 2026-07-13
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
Confirmed
Purity
Tested · passed · core
Reported purity percentage for the analyte.
98.80%
Heavy metals
Not on this certificate file
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Not on this certificate file · core
LAL or chromogenic endotoxin assay.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Sterility
Not on this certificate file
Sterility testing where applicable.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High HPLC purity confirmed
Peptide purity of 98.80% by HPLC is within normal range for research-grade peptides
Identity confirmed by mass spectrometry
BPC-157 identity confirmed using HPLC-QTOF MS method
Batch information present
COA number COA-2026-C82/TP1, Accession # ACC-2026-8813, Lot Number 240824B
Dates are current and consistent
Analysis date and date received both 07/13/2026, within acceptable timeframe relative to today (2026-07-28)
Laboratory information complete
ILS Laboratories with full contact information, signed by Dr. Greg Kalyazhny on 7/13/2026
Verification URL provided
QR code and URL for independent verification: portal.ils-labs.com/verify/coa/qe7cngqPPa_Tg
Limited testing scope
Only purity and identity panels performed; no heavy metals, microbial, endotoxin, sterility, or residual solvent testing. This is common for basic research peptide COAs but limits safety assurance
Professional presentation
Document includes HPLC chromatogram, clear tabular results, methodology notes, and professional formatting consistent with legitimate laboratory reports
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.