Public COA audit

BPC-157

Audited July 28, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
95%
Panels
2/7
Purity (printed)
98.8%

Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (2/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
COA-2026-C82/TP1
Identity method
HPLC-QTOF MS
Sample date
2026-07-13
Issue date
2026-07-13

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

2 of 7 present · 2 passed · 0 failed · 0 reported · 5 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    Confirmed

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    98.80%

  • Heavy metals

    Not on this certificate file

    Lead, arsenic, cadmium, mercury, or similar limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Microbial

    Not on this certificate file

    Bioburden / microbial limits testing.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Endotoxin

    Not on this certificate file · core

    LAL or chromogenic endotoxin assay.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Sterility

    Not on this certificate file

    Sterility testing where applicable.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High HPLC purity confirmed

    Peptide purity of 98.80% by HPLC is within normal range for research-grade peptides

  • Identity confirmed by mass spectrometry

    BPC-157 identity confirmed using HPLC-QTOF MS method

  • Batch information present

    COA number COA-2026-C82/TP1, Accession # ACC-2026-8813, Lot Number 240824B

  • Dates are current and consistent

    Analysis date and date received both 07/13/2026, within acceptable timeframe relative to today (2026-07-28)

  • Laboratory information complete

    ILS Laboratories with full contact information, signed by Dr. Greg Kalyazhny on 7/13/2026

  • Verification URL provided

    QR code and URL for independent verification: portal.ils-labs.com/verify/coa/qe7cngqPPa_Tg

  • Limited testing scope

    Only purity and identity panels performed; no heavy metals, microbial, endotoxin, sterility, or residual solvent testing. This is common for basic research peptide COAs but limits safety assurance

  • Professional presentation

    Document includes HPLC chromatogram, clear tabular results, methodology notes, and professional formatting consistent with legitimate laboratory reports

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.