Public COA audit
BPC-157
Audited September 5, 2026
Several fields check out, but we found issues worth reviewing before you rely on this document.
- Legitimacy
- 92
- Confidence
- 93%
- Panels
- 3/7
- Purity (printed)
- 99.47%
Scored high because the document is mostly consistent but carries soft concerns, limited panel coverage (3/7), and 1 soft concern. To improve: include identity, purity, and endotoxin at minimum.
Document details
Fields extracted from the certificate — not order or payment data.
- Batch / lot
- ny9k25d
- Identity method
- HPLC-UV-MS
- Sample date
- 2025-11-14
- Issue date
- 2025-11-25
Original certificate
Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.
7-panel checklist
Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.
3 of 7 present · 2 passed · 0 failed · 1 reported · 4 missing
Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.
Identity
Tested · passed · core
Compound identity confirmed (e.g. HPLC, mass spec).
ID Confirmed
Purity
Tested · passed · core
Reported purity percentage for the analyte.
99.47%
Heavy metals
Not on this certificate file
Lead, arsenic, cadmium, mercury, or similar limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Microbial
Not on this certificate file
Bioburden / microbial limits testing.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Endotoxin
Tested · result on file · core
LAL or chromogenic endotoxin assay.
Sterility
Not on this certificate file
Sterility testing where applicable.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
Residual solvent / water
Not on this certificate file
Residual solvents or water content limits.
No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”
How to read this
Had data · good
Panel present with a pass (or clear acceptance).
Had data · bad
Panel present with a fail — a concrete quality signal.
Had data · unclear
Value reported without an explicit pass/fail mark.
Missing on this file
Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.
Findings
Evidence-linked observations from this audit.
High HPLC purity confirmed
Chromatographic purity of 99.47% with clear dominant peak at retention time 5.22 minutes, consistent with high-quality peptide synthesis
Mass spectrum confirmation
Mass spectrum shows expected m/z 711 matching BPC-157 reference standard, with good spectral match
Batch number present
Lot number ny9k25d clearly documented with sample photos showing vial labeling
Dates within normal range
Sample received 2025-11-14, tested 2025-11-20, report issued 2025-11-25 - all dates are logical and sequential
Established testing laboratory
Krause Analytical LLC is a known peptide testing laboratory in Austin, TX with verification URL provided
Limited testing scope - purity/identity only
This COA covers purity and identity testing only. Methods summary on page 3 describes endotoxin and metals testing protocols, but results are not included in this report. This may be a split report where additional safety panels are documented separately.
Professional presentation
Document includes proper headers, watermarks, signature, chromatogram, mass spectra, and detailed methods summary consistent with professional analytical laboratory reporting
PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.