Public COA audit

PT-141 · Bremelanotide

Audited September 5, 2026

Mostly consistent, with concerns

Several fields check out, but we found issues worth reviewing before you rely on this document.

Legitimacy
92
Confidence
93%
Panels
6/7
Purity (printed)
99.742%

Scored high because the document is mostly consistent but carries soft concerns, broad panel coverage (6/7), and 1 soft concern.

Document details

Fields extracted from the certificate — not order or payment data.

Batch / lot
PT202605
Identity method
LC-MS
Issue date
2026-06-25

Original certificate

Embedded copy of the stored COA PDF or image. Download it for your records — PeptIQ’s audit is separate from the lab document itself.

Loading original certificate…

7-panel checklist

Had data + good, had data + bad, reported without pass/fail, or missing. Missing lowers thoroughness — you decide whether that panel matters; PeptIQ’s score still factors coverage.

6 of 7 present · 6 passed · 0 failed · 0 reported · 1 missing

Missing is a thoroughness gap — not automatically bad. PeptIQ’s legitimacy score still weighs panel coverage; you can down-weight panels that don’t matter for your use case.

  • Identity

    Tested · passed · core

    Compound identity confirmed (e.g. HPLC, mass spec).

    PT-141

  • Purity

    Tested · passed · core

    Reported purity percentage for the analyte.

    99.742%

  • Heavy metals

    Tested · passed

    Lead, arsenic, cadmium, mercury, or similar limits.

    As <0.15, Cd <0.05, Pb <0.5, Hg <0.3

  • Microbial

    Tested · passed

    Bioburden / microbial limits testing.

    No Growth

  • Endotoxin

    Tested · passed · core

    LAL or chromogenic endotoxin assay.

    Pass (≤0.5 EU/mL)

  • Sterility

    Tested · passed

    Sterility testing where applicable.

    No microbial growth detected

  • Residual solvent / water

    Not on this certificate file

    Residual solvents or water content limits.

    No evidence on this file. Vendors sometimes publish separate purity and endotoxin reports for the same lot — check the brand page before treating this as “never tested.”

How to read this

Had data · good

Panel present with a pass (or clear acceptance).

Had data · bad

Panel present with a fail — a concrete quality signal.

Had data · unclear

Value reported without an explicit pass/fail mark.

Missing on this file

Not on this certificate file. Lowers file thoroughness; a sibling endotoxin/purity report for the same lot may still exist. PeptIQ’s score still factors coverage.

Findings

Evidence-linked observations from this audit.

  • High purity confirmed

    Batch average purity of 99.742% with consistent individual vial results (99.571-99.869%) meets >98% specification. This is normal for research-grade peptides.

  • Identity confirmed by LC-MS

    PT-141 identity confirmed via LC-MS with matching molecular formula C50H68N14O10 and CAS 189691-06-3.

  • Comprehensive testing panel

    Document includes purity (HPLC), identity (LC-MS), endotoxin safety screen (≤0.5 EU/mL), heavy metals (4 analytes), microbial sterility, rapid sterility screening, and fentanyl presence analysis. Only residual solvent/water content not explicitly reported.

  • Batch conformity data provided

    Five individual vials tested with detailed purity and net content measurements, showing good batch consistency.

  • Issue date valid

    Certificate issued 2026-06-25, which is before the current date (2026-09-05). No sample collection date explicitly stated.

  • Lab identification and verification

    Kovera Labs identified with report number KVR-2026-28597D, access code DO7OP9D, and verification URL koveralabs.com/verify. Lab director signature present.

  • Professional presentation

    Well-formatted COA with clear sections, chromatogram included, product photo, QR code for verification, and comprehensive test results table.

  • Residual solvent/water content not reported

    No explicit Karl Fischer water content or residual solvent analysis visible in this report.

PeptIQ COA reports analyze document content and publicly verifiable lab signals. They are educational and not a guarantee of product quality, legality, or safety. Always consult a qualified professional before making health decisions. We never publish purchase prices, shipping details, or uploader identity.